Home | Browse Ads | Consumer Electronics | Radio

Allen Bradley PLC supplier ProSoft PLX31-EIP-MBS4

Item #108622
Qty: 9999

User
feng2012840 (0)
Seller Location
Shenzhen, CHN
Asking Price
$1.00
Expiration Date
12-06-2016
Date Posted
11/22/2016
Shipping Cost
Shipping Options
In the US and International
Payment Options
Other

INQUIRE ABOUT THIS LISTING

Description

Allen Bradley PLC supplier ProSoft PLX31-EIP-MBS4 ROC-Int is one of the largest PLC wholesale company from China, we export most of the famous automation plc include Siemens simatic S7, S5,Allen Bradley contrologix slc 500,Schneider 140 Modicon series PLC,Omron CJ1W PLC ect.Mitsubishi,A/Q series PLC. We have so large stock and wholesale price for below original, new and sealed items: Pro-Soft PLX31-EIP-MBS4 Pro-Soft PLX31-EIP-MBS4: Ethernet IP to 4 port serial Modbus gateway, 10/100 Base-T half duplex RJ45 connector ethernet port, 24VDC, 2500Vrms port signal isolation, 4000 word database, LED indication, -13 to 158 deg F operating temperature, 5.38 x 1.99 x 4.38 ProSoft Technologys EtherNet/IP to Modbus Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP PACs or devices and Modbus-enabled PACs or devices. EtherNet/IP PACs include Rockwell Automation ControlLogix and CompactLogix, as well as several Schneider Electric controllers. Modbus Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four ports allow for connectivity of up to 400 Modbus Serial devices, reducing the amount of gateways required for your application. In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance. Features Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data, optimizing Ethernet bandwidth. Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time. Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery. Four serial ports allow for connectivity of up to 400 Modbus devices, reducing the amount of gateways required for your application. ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet. Specifications : EtherNet/IP Specifications Specification Description Number of Class 3 Server Connections 5 Supported PLC Types PLC2, PLC5, SLC, CLX, CMPLX, MICROLX Supported Message Types PCCC and CIP Class 3 Client Connections Connected - 2 Unconnected - 1 Number of Class 1 I/O Connections 8 I/O connection sizes 248/248 Max RPI time 5 ms per connection CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write Command List Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. Command Sets PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500 Command Set Modbus Serial Specifications Specification Description Command List Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count. Supported Modbus Function Codes 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (Slave Only) 23: Read/Write Holding Registers (Slave Only) Software configurable communication parameters Baud rate: 110 baud to 115.2 kbps Parity: None, Even, Odd Data Size: 7 or 8 bits Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds Modbus RTU mode (binary) with CRC-16 Modbus ASCII mode with LRC error checking Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations Polling of Command List Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained per active Modbus Master port. Node Address 1 to 247 (software selectable) RS Interface RS232, RS422, and RS485 Transmit and Receive Buffer Size 255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character Where Automation Connects Global Distribution ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: www.prosoft-technology.com Global Support We are there for you All ProSoft Technology products are backed with free technical support. Contact our worldwide Technical Support team directly by phone or email. Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: www.prosoft-technology.com Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Hardware Specifications Specification Description Power Supply 24 VDC nominal 10 to 36 VDC allowed Positive, Negative, GND Terminals Current Load 24 VDC nominal @ 300 mA 10 to 36 VDC @ 610 mA maximum Operating Temperature -25C to 70C (-13F to 158F) Storage Temperature -40C to 80C (-40F to 176F) Shock IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational) IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational) Vibration IEC 60068-2-6; 5G @ 10 to 150 Hz Relative Humidity 5% to 95% RH with no condensation Dimensions (H x W x D) 5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm LED Indicators Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), Module Configuration Status (EtherNet/IP Only) Ethernet Communication Port Link/Activity, and 100 mbit Serial Communication Port Receive (RX) and Transmit (TX) Ethernet Port 10/100Mbit half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency is less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration Number of Serial Ports 4 Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF (Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x (Si8440,Si8441,Si8442) Shipped With Each Unit 2.5 mm screwdriver ProSoft Solutions DVD J180 Power Connector (1) RJ45-DB9M Serial Adapter Cable (serial protocol) (1) DB9 to Screw Terminal Adapter (serial protocol) 5 straight-through Ethernet cable Note: ROC-Int provide door-to-door express delivery services. Payment Options:T/T, Western Union,paypal  Shipping ways: DHL TNT,Feedex,EMS ect Warranty: All the products are 12 months warranty start  from the date of order sent out Items condition: original package and new, sealed. Business Hours:MonSat  8:00pm 6:00pm

INQUIRE ABOUT THIS LISTING

Login

Register